TENCAN Glove Box with Purification System
Application
Applies to making pure environment with removal of water, oxygen and dust.
R&D and production of battery industry (Lithium ion battery, powder battery, solar cell, lithium ion phosphate battery ).
Overview
Applies to making pure environment with removal of water, oxygen and dust.
R&D and production of battery industry (Lithium ion battery, powder battery, solar cell, lithium ion phosphate battery ).
R&D and manufacture of special lamp (HD lamp, metal halide lamp, ceramic metal halide lamp).
Welding (resistance welding, TIG welding, laser welding, plasma welding, brass solder)
R&D and production of OLED
R&D and production of pharmaceuticals
R&D and production of super capacitors
Fine chemical industry
Nuclear industry
R&D and production of new energy materials
Working Principle
The box and purification system are connected together and they both form a well-sealed working environment. When inert gas or nitrogen is filled into the box continuously, the active substances inside the box shall be removed circularly out of the box to keep the inner box in a high cleanness and a high purity inert gas environment (water content≤1 ppm, oxygen content ≤1 ppm) all the time.
Feature/Advantage
Glove box with purification system is a kind of laboratory device which can be filled with a high purity inert gas into the box and active substances can be filtered out of the box circularly. It is also called “vacuum glove box with water and oxygen removal”, and “inert gas purification glove box”. Main functions of this kind of glove box: water content removal, oxygen content removal, other organic gas removal. It is widely used for making high pure environment without water, oxygen and dust content.
Data Sheet
| TECHNICAL DATA OF TENCAN INERT GAS GLOVE BOX WITH PURIFICATION SYSTEM | |
| Items | Data |
| Water content under the standard condition (Note: The standard condition is one atmospheric pressure, constant temperature of 20 degrees) | ≤1ppm |
| Oxygen content under the standard condition (The standard condition is one atmospheric pressure, constant temperature of 20 degrees ) | ≤1ppm |
| Max Vacuum Degree which the transition cabinet bears | <100pa |
| Leakage Rate | ≤ 0.05vol%/h |
| Gas presure range inside the box | -3000pa~+3000pa |
| Specifications of Standard Model of Purification Glove Box | ||||||
| No. | Model No. | Box Dimensions | Total Dimensions | Operating Sides | Numbers of Gloves | Options |
| 1 | GBP800S-2 | 1200*800*930mm | 1915*830*1830mm | Single | 2 | Single or double purification columns |
| 2 | GBP1000S-2 | 1200*1000*930mm | 1915*1060*1830mm | Single | 2 | Single or double purification columns |
| 3 | GBP1000D-4 | 1200*1000*930mm | 1915*1060*1830mm | Double | 4 | Single or double purification columns |
| 4 | GBP1200S-2 | 1200*1200*930mm | 1915*1260*1830mm | Single | 2 | Single or double purification columns |
| 5 | GBP1200D-4 | 1200*1200*930mm | 1915*1260*1830mm | Double | 4 | Single or double purification columns |
| 6 | GBP800S-3 | 1500*800*930mm | 2215*1060*1830mm | Single | 3 | Single or double purification columns |
| 7 | GBP1000S-3 | 1500*1000*930mm | 2215*1060*1830mm | Single | 3 | Single or double purification columns |
| 8 | GBP1000D-6 | 1500*1000*930mm | 2215*1060*1830mm | Double | 6 | Single or double purification columns |
| 9 | GBP1200S-3 | 1500*1200*930mm | 2215*1260*1830mm | Single | 3 | Single or double purification columns |
| 10 | GBP1200D-6 | 1500*1200*930mm | 2215*1260*1830mm | Double | 6 | Single or double purification columns |
| 11 | GBP800S-4 | 1900*800*930mm | 2615*1060*1830mm | Single | 4 | Single or double purification columns |
| 12 | GBP1000S-4 | 1900*1000*930mm | 2615*1060*1830mm | Single | 4 | Single or double purification columns |
| 13 | GBP1000D-8 | 1900*1000*930mm | 2615*1060*1830mm | Double | 8 | Single or double purification columns |
| 14 | GBP1200S-4 | 1900*1200*930mm | 2615*1260*1830mm | Single | 4 | Single or double purification columns |
| 15 | GBP1200D-8 | 1900*1200*930mm | 2615*1260*1830mm | Double | 8 | Single or double purification columns |
Notes:
Cabinet water and oxygen content under the standard condition:
Water content ≤1ppm, oxygen content≤1 ppm (Note: Standard condition is that an atmospheric pressure, constant temperature of 20 degree).
Leakage Rate: ≤0.05Vol%/ h (subject to change value of oxygen content in box)
Used Gas:
a) Working Gas: N2、Ar、He and etc.
b) Controlling Gas: Compressed air or Inert Gas.
C) Restoring Gas: Mixed gas of working gas and hydrogen.
Restoring gas is as same as working gas if there is only water removal system or oxygen removal system.
Remarks: All Single side boxes of 4 gloves are assembled glove box. Numbers of assembled box can be ordered as per customer’s needs. Quantity of purification columns is also designed to be matched according to customer’s requirements
Mactchable Accessory
| TECHNICAL DATA OF TENCAN INERT GAS GLOVE BOX WITH PURIFICATION SYSTEM | |
| Items | Data |
| Water content under the standard condition (Note: The standard condition is one atmospheric pressure, constant temperature of 20 degrees) | ≤1ppm |
| Oxygen content under the standard condition (The standard condition is one atmospheric pressure, constant temperature of 20 degrees ) | ≤1ppm |
| Max Vacuum Degree which the transition cabinet bears | <100pa |
| Leakage Rate | ≤ 0.05vol%/h |
| Gas presure range inside the box | -3000pa~+3000pa |
| Specifications of Standard Model of Purification Glove Box | ||||||
| No. | Model No. | Box Dimensions | Total Dimensions | Operating Sides | Numbers of Gloves | Options |
| 1 | GBP800S-2 | 1200*800*930mm | 1915*830*1830mm | Single | 2 | Single or double purification columns |
| 2 | GBP1000S-2 | 1200*1000*930mm | 1915*1060*1830mm | Single | 2 | Single or double purification columns |
| 3 | GBP1000D-4 | 1200*1000*930mm | 1915*1060*1830mm | Double | 4 | Single or double purification columns |
| 4 | GBP1200S-2 | 1200*1200*930mm | 1915*1260*1830mm | Single | 2 | Single or double purification columns |
| 5 | GBP1200D-4 | 1200*1200*930mm | 1915*1260*1830mm | Double | 4 | Single or double purification columns |
| 6 | GBP800S-3 | 1500*800*930mm | 2215*1060*1830mm | Single | 3 | Single or double purification columns |
| 7 | GBP1000S-3 | 1500*1000*930mm | 2215*1060*1830mm | Single | 3 | Single or double purification columns |
| 8 | GBP1000D-6 | 1500*1000*930mm | 2215*1060*1830mm | Double | 6 | Single or double purification columns |
| 9 | GBP1200S-3 | 1500*1200*930mm | 2215*1260*1830mm | Single | 3 | Single or double purification columns |
| 10 | GBP1200D-6 | 1500*1200*930mm | 2215*1260*1830mm | Double | 6 | Single or double purification columns |
| 11 | GBP800S-4 | 1900*800*930mm | 2615*1060*1830mm | Single | 4 | Single or double purification columns |
| 12 | GBP1000S-4 | 1900*1000*930mm | 2615*1060*1830mm | Single | 4 | Single or double purification columns |
| 13 | GBP1000D-8 | 1900*1000*930mm | 2615*1060*1830mm | Double | 8 | Single or double purification columns |
| 14 | GBP1200S-4 | 1900*1200*930mm | 2615*1260*1830mm | Single | 4 | Single or double purification columns |
| 15 | GBP1200D-8 | 1900*1200*930mm | 2615*1260*1830mm | Double | 8 | Single or double purification columns |
Notes:
Cabinet water and oxygen content under the standard condition:
Water content ≤1ppm, oxygen content≤1 ppm (Note: Standard condition is that an atmospheric pressure, constant temperature of 20 degree).
Leakage Rate: ≤0.05Vol%/ h (subject to change value of oxygen content in box)
Used Gas:
a) Working Gas: N2、Ar、He and etc.
b) Controlling Gas: Compressed air or Inert Gas.
C) Restoring Gas: Mixed gas of working gas and hydrogen.
Restoring gas is as same as working gas if there is only water removal system or oxygen removal system.
Remarks: All Single side boxes of 4 gloves are assembled glove box. Numbers of assembled box can be ordered as per customer’s needs. Quantity of purification columns is also designed to be matched according to customer’s requirements